Process Moisture Analyzer - Michell Promet EExd

Updated:2025-03-13

Views:186

  • Brand: PST/Michell
  • Model: Promet EExd
  • Description: Promet EExd Process Moisture Analyzers are hazardous-area rated industrial hygrometer systems for measurement of water vapor content in process gases on natural gas platforms and terminals as well as
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Process Moisture Analyzer - Michell Promet EExd Description:

Product Manual Datasheet

Natural Gas Water Dew-Point Analyzer

Features

EExd flameproof certified - IECEx, ATEX, UKCA, cQPSus and TR CU Ex

Complete hazardous area installation

Single- or dual-channel measurement

Moisture content, dew point and pressure

Calibration traceable to NPL (UK) and NIST (USA)

Range -120...+30°Cdp (-184...+86°F), 0.001...30,000 ppmV

Remote global access options

Sour gas compatible

Field calibration maintenance

Promet EExd Process Moisture Analyzers are hazardous-area rated industrial hygrometer systems for measurement of water vapor content in process gases on natural gas platforms and terminals as well as in petrochemical plants and industrial manufacturing facilities.

The Promet EExd is installed directly in the hazardous area, simplifying site installation and retrofits. Promet EExd combines proven Michell moisture sensing technologies with sample conditioning systems designed to provide a reliable and easy-to-operate, multi-channel, on-line instrument for moisture measurement in flammable gases.

Specifications

Channel Configurations Single and two channel
Moisture Parameters Dew point °C and °F
Moisture Content Automatic pressure compensated conversions:
ppmV for natural gas and ideal gas lb/mmscf and mg-m-3 for natural gas Dew point at a pressure input by the user for natural gas and ideal gas.
Calculations for natural gas moisture content based on either IS0 18453 or IGT#8 to customer order preference.
Analysis Pressure barg, MPa and psig
Sensor Technology Michell Ceramic Metal-Oxide Moisture Sensor
Measurement Range -120oC dp...+30oC dp (-184...+86 °F)
1 ppbV...30,000 ppmV
0...250 barg (0...3625 psig)
Calibration Range -100 °C dp...+20 °C dp (-148 °F dp...+68 °F dp)
10 ppbV...23,000 ppmV
Accuracy Dew point: ±1 °C between –59.9 & +20 °C dp (±1.8 °F between -75.8 & 68 °F dp)
Moisture content: ±10 % of reading
Dew point: ±2 °C between –60 & -100 °C dp (±3.6 °F between -76 & -148 °F dp)
Moisture content: ±20 % of reading
Analysis Pressure: ±0.25 % FS.
Measured Resolution 0.1 °C (0.18 °F): –80...+20 °C dp (-112...+68 °F)
1 °C (1.8 °F): –100...-80 °C dp (-148...-112 °F)
Displayed Resolution Dew point: 0.1 °C (0.18 °F)
Moisture content: autoscale, 5 digits
MPa and BarG: 0.1, psig: 1.0
Resolution 0.1 °C between +20 °C dp and -80 °C dp (0.18 °F between +68 and -112 °F dp)
1 °C between -80 °C dp and -100 °C dp (1.8 °F between -112 and -148 °F dp)
Temperature Coefficient Algorithm compensation (-20...+50 °C)
HMI: Keyboard Interface Capacitive touch-screen through glass
Display Vacuum fluorescent
Datalogging A rolling maximum of 150 data logs is available.
Each log records time, date, moisture and pressure values for each channel.
5 minutes minimum and 60 minutes maximum logging intervals can be set by the user
Communications and Output Two non-isolated 4...20 mA per measurement channel. 500 Ω maximum load. Range and parameter settable by user.
Modbus RTU @ 9600 baud-rate
Alarms: two volt free contacts per channel; one process value and one instrument status. Also available via Modbus communications
Main Unit Enclosure Internal temperature control for condensation protection and stable analysis conditions
Type Explosionproof NEC/Flameproof EExd
Construction Cast copper-free aluminium
Finish Chromate primer, Polyester P9010 powder coated (black). Meets BS3900
Operating Pressure 30...138 barg (435...2000 psig)*
Sample Connections 1/8” NPT (F)
Sample Flow Rate 1 Nl/min (Nm3/hr) (2.1 scfh)
Sample Flow Alarm Optional
Power Supply 90...260 V AC, 50/60 Hz, 180 W Main Unit
Operating Environment Indoor/Outdoor -20 °C...+60 °C (-4...+140 °F)
Max 95 % rh. Shaded location
Certification
Hazardous Area Certification ATEX/UKCA: II 2 G Ex db IIB+H2 Gb
T5 (Tamb -40 °C...+44 °C) – 60 barg max.
T4 (Tamb -40 °C...+60 °C) – 60 barg max.
T3 (Tamb -40 °C...+60 °C) – 138 barg max.

IECEx: Ex db IIB+H2 Gb
T5 (Tamb -40 °C...+44 °C) – 60 barg max.
T4 (Tamb -40 °C...+60 °C) – 60 barg max.
T3 (Tamb -40 °C...+60 °C) – 138 barg max.

cQPSus: Class I, Division 1
Groups B, C & D
T5 (Tamb -25 °C...+44 °C) – 60 barg max.
T4 (Tamb -25 °C...+60 °C) – 60 barg max.
T3 (Tamb -25 °C...+60 °C) – 138 barg max.

CL I ZONE 1: Ex db IIB+H2 Gb
AEx db IIB+H2 Gb
T5 (Tamb -40 °C...+44 °C) – 60 barg max.
T4 (Tamb -40 °C...+60 °C) _ 60 barg max.
T3 (Tamb -40 °C...+60 °C) – 138 barg max.
Additional TRCU 012 (EAC), PESO (India), KCS (Korea), Ukraine Ex
Pattern Approval GOST-R, GOST-K
*Other variants available to customer specific order – consult Michell Instruments

Suitable Applications

Natural gas glycol dehydration

Offshore export pipeline natural gas

Transmission pipeline monitoring

Hydrogen production, storage and transportation including natural gas injection

LNG production

Ethylene feed stock to polymer plant

Speciality gas production

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 草b视频 | 久久精品亚洲精品 | 奇米在线视频 | 久久r精品 | 日韩亚洲综合精品国产 | 一个人看的www片高清小说 | 国产91在线播放 | 同性老色老头tv老头东 | 高跟翘臀老师后进式视频 | 国产黄色小视频在线观看 | 日本高清视频在线免费观看 | 申奥演员| 91蝌蚪国产 | 在线播放亚洲精品富二代91 | 久久一码二码三码区别 | 久草小区二区三区四区网页 | 欧美透逼视频 | 国产亚洲欧美另类一区二区三区 | 欧美色欧美亚洲另类七区 | 国产精品爱久久电影 | 久久都是精品 | 亚洲亚洲人成网站在线观看 | 蜜桃视频在线观看免费视频网站www | 日韩精品久久久久久久电影 | 男女爱爱免费网站视频在线观看 | 亚洲色婷婷久久精品AV蜜桃 | 夜夜骑日日 | 五月花综合网 | 激情五月深爱五月 | 操操操美女 | 色婷婷久久综合中文网站 | 国产一级免费视频 | 亚洲第九十九页 | 亚洲国产人久久久成人精品网站 | 艹久久 | 青青草18 | 国产高清视频免费在线观看 | 成人小视频网 | 欧美图片一区二区三区 | 天干夜天天夜天干天ww | 67194免费毛片入口在线看 |