www.黄色毛片 I 午夜剧场一级片 I 色婷婷中文 I 五级黄色片 I 日本精品一区二区在线观看 I 国产福利三区 I 午夜黄视频 I av无码av高潮av喷吹免费 I 98超碰在线 I 亚洲夜夜爱 I 嘿咻视频在线观看 I 天天爽夜夜爽视频精品 I 久久久久1 I 欧美一级片网址 I 色老二导航 I 久久久一区二区精品 I 你懂的91 I 亚洲乱码中文论理电影 I 国产黄色免费片 I 亚洲国产精品久久久久秋霞影院 I 99中文字幕 I 中文字幕四区 I 在线三级av I 青青草手机视频 I www.亚洲视频.com I 欧美日韩国产成人高清视频 I 国产精品爱久久久久久久电影 I 免费嗨片首页中文字幕 I 天天色综合4 I 日韩中文字幕免费在线观看 I 久久国产精品网站 I 在线免费观看福利影院 I 成人丁香在线 I 米奇777影视狠狠狠 I 色噜噜狠狠色综合欧洲selulu

Products

current position:home page>Products>Analysis Instrument>PST>

S8000 -100 High Precision Chilled Mirror Hygrometer PST/Michell

Updated:2025-03-13

Views:216

  • Brand: PST/Michell
  • Model: S8000 -100
  • Description: The S8000 -100 hygrometer directly measures the formation of condensation on a mirrored surface, offering the widest possible measurement range of -100...+20 °C frost/dew point. It uses a unique advan
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

S8000 -100 High Precision Chilled Mirror Hygrometer Description:

Product Manual

The New Laboratory Humidity Reference Standard

Features

Accuracy of ±0.1 °C (±0.18 °F)

Precision measurement to -100 °C (-148 °F) frost point (13.8 ppbV) with no need for additional cooling

Reproducibility of ±0.15 °C (±0.27 °Ffp) at -100 °C (-148 °Ffp) frost point

Simple configuration and operation via touch screen interface

Sensor optimized for fast response to low moisture levels

External 4-wire Pt100 connections

Microscope for visual inspection of condensate on mirror

Compact 19” x 4U package for flexibility of installation

Ethernet or USB connections

SD card data logging

The S8000 -100 hygrometer directly measures the formation of condensation on a mirrored surface, offering the widest possible measurement range of -100...+20 °C frost/dew point. It uses a unique advanced dual optics system which detects small changes in moisture condensed on the mirror surface. This results in a very high sensitivity and fast response to changes in frost point, even at very low moisture levels where measurements are most challenging. Fully automated control of the system means that no operator intervention is required. The instrument provides a range of Modbus digital communications, and analog outputs allowing it to be monitored remotely or via specific S8000 -100 logging software. 4-wire Pt100 connections are provided on the rear panel for remote mirror temperature monitoring. A high-contrast touch-screen LCD display gives or presents entirely customizable local indication of the measured values, along with a trend graph and fault warnings.

Specifications

Dew-Point Sensor
Measurement Range -100...+20 °C (-148...+68 °F) frost/dew point
Measurement Accuracy* ±0.1 °C (±0.18 °F)
Reproducibility at -100 °Cfp ±0.15 °C (±0.27 °F)
Stability at -100 °Cfp ±0.1 °C (±0.09 °F)
Speed of Response <2hrs to ±0.25 °C (±0.45 °F) stability @-90 °Cfp (-130 °Ffp)
<6hrs to ±0.25 °C (±0.45 °F) stability @-100 °Cfp (-148 °Ffp)
Temperature dependence at -100 °C (-148 °F) ±0.15 °Cfp (±0.27 °Ffp) per 1 °C (1.8 °F) environmental temperature change
Mirror Gold-plated copper
Temperature Measurement 4-wire Pt100, 1/10 DIN class B
Sample Flow Rate 500...1000 ml/min (recommended 750 ml/min)
Sample Gas Pressure 1.6 bara (23.2 psia) max
Pressure Sensor
Measurement range 0...1.6 bara (23.2 psia)
Measurement Accuracy Accuracy 0.25% FS Typical
Thermal error 1.5% FS Typical
Drift 0.2% FS/p.a non-cumulative
Temp Comp -20 °C...+80 °C (-4 °F...+176 °F)
Flow Sensor
Measurement Range 0 to 1000ml/min
Measurement Accuracy ±1.5% FS (10...100% of rated flow)
Monitor
Resolution User selectable to 0.001 °C (0.0018 °F), depending on parameter
Measurement Units °C dew/frost point, °C temperature, ml/min flow, bara pressure
Calculated units Relative humidity – %, Absolute humidity – g/m3, ppmV, Mixing Ratio – g/kg, Wet Bulb Temperature (Twb) – °C, °F, Water Vapor Pressure (wvp) – Pa, Pressure converted DP – °C, °F, Pressure – kPa, Barg, Psia, Psig
Outputs Analog: 2x active mA outputs, configurable 0...20 mA or 4...20 mA
Digital: Modbus RTU over USB
Optional: Modbus RTU over RS485/RS232, Modbus TCP over Ethernet
Alarm: 1x Process Relay
1x Alarm Relay
Both Form C, 1 A, 30 V DC
User Interface 5.7" LCD with touchscreen
Data Logging SD Card (8GB supplied) and USB interface.
Supports SD Card (FAT-32) – 32 GB max. that allows 24 million logs or 560 days, logging at 2-second intervals
Environmental Conditions +5 °C...+30 °C (+41 °F...+86 °F)
Power Supply 85 to 264 V AC
Power Consumption 185 VA
Mechanical Specification
Dimensions (W x H x D) 440 mm x 185 mm x 515 mm (17.32” x 7.28” x 20.28”)
Weight 22 kg (48.5 lb)
Sample Gas Connections Inlet: ?" VCR
Outlet: ?" Swagelok
General
Optional Remote Temperature Probe 4-wire Pt100, 1/10 DIN class B, 2m cable
Calibration 5-point UKAS calibration to -90 °Cfp (-130 °Ffp) + -100 °Cfp (-148 °Ffp)


* Measurement accuracy means maximum deviation between instrument under test and corrected reference. To this must be added the uncertainties associated with the calibration system and the environmental conditions during testing or subsequent use.

Applications

Reference humidity measurements in standards laboratories

Reference instrument in humidity calibration facilities

Precision moisture measurements in research and development

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com