LEAK CURRENT HiTESTER ST5540 Description:

Orientation Pack Brochure

To ensure the safe use of electrical products, electrical safety tests such as insulation resistance, withstand voltage, ground resistance, and leakage current must always be conducted. Hioki Leakage Current Testers comply with laws and standards regarding medical electrical equipment as well as non-medical electrical equipment, and can be used to measure leakage current in all types of electrical products from computers to medical equipment.

The ST5540 consists of measurement networks that simulate the human body and a high-frequency volt meter, and is also capable of switching power supply polarities and making measurements under simulated single fault conditions in equipment under test.

Leak Current Measurement - Essential to Electrical Safety

The ST5540 series features an improved measuring method and dramatically faster cycle times thanks to its uninterrupted polarity switching capability. The new devices support rated currents of up to 20A, making it more than ideal for use with products built to new standards.

Leak Current Testing of Medical Electrical Devices

In order to prevent the danger of electric shock, electrical devices use power supplies that are isolated from parts of the device that may come into contact with the body. However, it is impossible to achieve infinite insulation resistance. Some leak current always exists, and its magnitude changes as the insulation degrades over time. The LEAK CURRENT HiTESTER ST5540/ST5541 provides an easy-to-operate solution for measuring leak current in electrical devices, making it eminently suitable for use in an extensive array of applications, ranging from production lines to equipment maintenance and inspections.

Key Features

Compliance with IEC 60601-1:2005 Ed 3.0, JIS T 0601-1:2012 for medical-use electrical devices and essential to electrical safety (*1)

Compliance with Electrical Appliances and Materials Safety Act, JIS, IEC, and UL standards for general-use electrical devices

Uninterrupted polarity switching function dramatically reduces cycle time

Support for rated currents up to 20 A gives the instrument more than adequate capability for testing products designed to comply with new standards

Communications functionality and external I/O support allow automatic testing on production lines

Basic specifications

Measurement methods Measurement of voltage drop across body simulated resistance points, Calculation and display of current values, True rms measurement, Measurement unit floats relative to instrument ground.
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
Standards compliance
(NW: Body simulated resistance)
[NW-A] ? Electrical Appliances and Materials Safety Act
[NW-B1] ? Medical electrical equipment: IEC 60601-1:1988+ A1:1993+ A2:1995, JIS T 0601-1:1999
[NW-B2] ? Medical electrical equipment: IEC 60601-1:2005+ A1:2012, JIS T 0601-1:2012 and complement 1:2014, IEC 62353
[NW-C]
? Measurement of touch current and protective conductor current: IEC 60990:2016
? Electrical equipment for measurement, control, and laboratory use: IEC 61010-1:2010+ A1:2016
? Information technology equipment: IEC60950-1:2005+ A1:2009+ A2:2013
? Audio, video and similar electronic apparatus: IEC 60065:2014
? Personnel Protection Systems for EV: UL 2231-1:2012 (Amended 2016), UL-2231-2:2012 (Amended 2016)
[NW-D] ? For UL: UL 1492:1996 (Amended 2013)
[NW-G] ? Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1:2010+ A1:2016
Leak current measurement Ground leak current, 3 types of contact current, 7 types of patient leak current, patient measurement current, 4 types of total patient leak current, free current measurement, 3 types of enclosure leak current
Measurement current DC, AC (true rms, 0.1 Hz to 1 MHz), AC+DC (true rms, 0.1 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
Measurement ranges DC / AC / AC+DC mode: 50.00 mA/ 5.000 mA/ 500.0 μA/ 50.00 μA
AC peak mode: 75.0 mA/ 10.00 mA/ 1.000 mA/ 500.0 μA
Measurement accuracy
(current measurement)
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
Interfaces External I/O, medical device relay output, USB 1.1 (communications), RS-232C
Functionality 110% voltage application, automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
Power supply 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Target device power supply input 100 to 250 V AC, 50/60 Hz Rated current input from terminal block: 20 A
Target device power supply output Output from terminal block: 20 A Output from outlet: 15 A
Dimensions and mass 320 mm (12.60 in)W × 110 mm (4.33 in)H × 253 mm (9.96 in)D, 4.5 kg (158.7 oz)
Included accessories Test lead L2200 (for ST5540, Red ×2, Black ×1) ×1 set, Enclosure probe 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, CD-ROM ×1

ST5540, ST5541 List of functions (Network)

Item ST5540 ST5541
Network A
(Electrical Appliances and Materials Safety Act)
Network B (Medical-use electrical devices) -
Network C (IEC 60990)
Network D (UL)
Network E (General-purpose 1)
Network F (General-purpose 2)
Network G (IEC 61010-1)

List of functions (Major functions)

Item ST5540 ST5541
Power on polarity switching function
Rated current 20 A
Function for checking for blown fuses
Frequency band switching -
110% voltage output terminal (T3 terminal) -
S10, S12, S13, E terminal -

List of functions (Testing leakage current mode)

Item ST5540 ST5541
Earth leakage current
Touch current
Patient auxiliary current -
Patient leakage current -
Total patient leakage current -
Free current
Enclosure - Earth leakage current
Enclosure - Enclosure leakage current
Enclosure - Line leakage current
Patient leakage current I -
Patient leakage current II -
Patient leakage current III -

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 狠狠入ady亚洲精品经典电影 | 久久精品视频在线看15 | 国产婷婷高清在线观看免费 | 99热久久国产精品免费观看 | 久草手机视频 | 天天爽夜夜爽人人爽免费 | 亚洲免费人成在线视频观看 | 99精品视频一区在线视频免费观看 | 色综合一区二区三区 | 操老逼 | 色婷婷网 | 一级大黄毛片 | 欧美亚洲一级 | 久久中文字幕一区 | 国产yin乱大巴视频 欧美在线三级 | 国内视频一区二区三区 | 九九热精品在线 | 日本一级做人免费视频 | 成人午夜精品一区二区三区 | 黄色一级免费 | 91麻豆精品国产91久久久无需广告 | 久久久精品 | 久久无码人妻国产一区二区 | 不卡免费视频 | 国产精品一区二区在线 | 久久不卡 | av在线免费看网站 | 91成人免费在线视频 | 亚洲天堂岛国片 | 亚洲综合色视频在线观看 | 久久精品日产第一区二区三区 | 亚洲一区二区三区一品精 | 亚洲国产成人精品激情 | 玖草资源在线 | www.成人| 香蕉视频亚洲一级 | 国产又大又粗又硬又长A片小说 | 天天干夜夜怕 | 日本精品一区二区 | 波多野结衣办公室jian 情 | 亚洲电影免费观看国语版 |