www.黄色毛片 I 午夜剧场一级片 I 色婷婷中文 I 五级黄色片 I 日本精品一区二区在线观看 I 国产福利三区 I 午夜黄视频 I av无码av高潮av喷吹免费 I 98超碰在线 I 亚洲夜夜爱 I 嘿咻视频在线观看 I 天天爽夜夜爽视频精品 I 久久久久1 I 欧美一级片网址 I 色老二导航 I 久久久一区二区精品 I 你懂的91 I 亚洲乱码中文论理电影 I 国产黄色免费片 I 亚洲国产精品久久久久秋霞影院 I 99中文字幕 I 中文字幕四区 I 在线三级av I 青青草手机视频 I www.亚洲视频.com I 欧美日韩国产成人高清视频 I 国产精品爱久久久久久久电影 I 免费嗨片首页中文字幕 I 天天色综合4 I 日韩中文字幕免费在线观看 I 久久国产精品网站 I 在线免费观看福利影院 I 成人丁香在线 I 米奇777影视狠狠狠 I 色噜噜狠狠色综合欧洲selulu

Products

current position:home page>Products>Measuring Instrument>Apogee>

SO-120: Soil Response Thermocouple Reference Oxygen Sensor

Updated:2025-03-13

Views:154

  • Brand:APOGEE
  • Model: SO-120
  • Description: The SO-120 has a standard response time of 60 seconds, is designed for use in soil applications, and has high-quality cable terminating in pre-tinned pigtail leads for easy connection to dataloggers a
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

SO-120: Soil Response Thermocouple Reference Oxygen Sensor Introduction:

user's manual

The SO-120 has a standard response time of 60 seconds, is designed for use in soil applications, and has high-quality cable terminating in pre-tinned pigtail leads for easy connection to dataloggers and controllers. It comes with a thermocouple wire to correct for temperature changes and a restive heater to raise the temperature of the membrane approximately two degrees above ambient temperature to keep condensation from occurring on the Teflon membrane and blocking the diffusion path of the sensor. Typical applications include measurement of O2 in laboratory experiments, monitoring gaseous O2 in indoor environments for climate control, monitoring of O2 levels in compost piles and mine sailings, monitoring redox potential in soils, and determination of respiration rates through measurement of O2 consumption in sealed chambers or measurement of O2 gradients in soil/porous media.



SO-120 Technical Drawing:


SO-120 Specification:

Measurement Range 0 to 100 % O?
Sensitivity (at sea level, 101.3 kPa) 52-58 mV in 21 % O?, 2.6 mV per % O?, 26 μV per 0.01 % O?
Response Time (time required to read 90 % of saturated response) 60 seconds
Output at 0 % O2 5 % of output at 20.95 % O? or 2.5 ± 1 mV
Measurement Repeatability Less than 0.1 % of mV output at 20.95 % O?
Non-linearity Less than 1 %
Signal Decrease per Year 1.8 % per year (1 mV per year)
Oxygen Consumption Rate 0.1 μmol O? per day at 20.95 % O? and 23 C
Operating Environment -20 to 60 C, 0 to 100 % relative humidity (non-condensing), 60 to 140 kPa
Input Voltage Requirement 12 V DC continuous (for heater), 2.5 V DC excitation (for thermistor)
Heater Current Drain 6.2 mA (74 mW power requirement when powered with 12 V DC source)
Thermistor Current Drain 0.1 mA DC at 70 C (maximum, assuming input excitation of 2.5 V DC)
Dimensions 32 mm diameter, 68 mm length
Mass 175 g (with 5 m of lead wire)
Cable 5 m of six conductor, shielded, twisted-pair wire
Warranty 4 years against defects in materials and workmanship
Manufactured Made in the USA

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com