MantaRay Portable Area Velocity Flow Meter Description:

User's Manual Datasheet

The MantaRay is a portable area velocity meter that measures flow using a submersible ultrasonic sensor. The unit is designed for flow surveys in open channels, partially-full sewer pipes, and surcharged pipes – making the portable open channel flow meter suitable for sewer monitoring, industrial flow monitoring, irrigation flow, and natural streams.

Easy to Use

The MantaRay Portable Area-Velocity Flow Meter measures both level and velocity to calculate flow in an open channel or pipe. Calibration is simple: enter the pipe diameter or channel dimensions and the MantaRay automatically computes and displays the flow rate and total on its backlit LCD display.

The ultrasonic sensor mounts inside the pipe or on the bottom of a channel with a stainless-steel mounting bracket (included) and a single screw into the bottom of the pipe or channel. No special compounds, tools, or hardware are required. The sensor is completely sealed with no orifices or ports, making it resistant to build-up and fouling.

Sleep Mode for Extended Battery Life

Use the MantaRay’s ‘Sleep Mode’ function to extend battery life while logging flow. The digital display, outputs, and non-essential functions are suspended during sleep mode. Based on the logger interval, the MantaRay activates the sensor for 12 seconds to obtain flow readings and then resumes low power mode until the next logger sample interval. To indicate that sleep mode has been activated, the digital display flashes every few seconds while sleeping.

External Battery Input

Connect external 12 or 24 V DC batteries to extend the MantaRay’s operating time indefinitely. Or connect the battery charger supplied with each flowmeter for continuous operation or long-term 4-20mA output and relay operation.

Suitable for Portable Flow Monitoring

Because of the portability of the MantaRay, the unit is ideal for applications such as flow verification, sewer flow monitoring, and reporting, industrial effluent monitoring, stormwater monitoring, natural streams, and irrigation water.

Features

Measures flow in partially filled pipes and open channels

No flume or weir required

4-20 mA and relay outputs for connection to Samplers and SCADA

Powered with built-in, rechargeable NiMH batteries

2 million point data logger with USB output to flash drives

Backlit LCD display for flow rate, totalizer, and menu system

Specifications

Channel Types Round pipe, rectangular, trapezoid, egg, or custom shapes
Electronics Enclosure IP 67 polycarbonate
Accuracy Level: ±0.25% of range or 1 mm (0.04 in).
Velocity: ±2% of Reading
Repeatability & Linearity ±0.1%
Display White, back-lit matrix - displays flow rate, totalizer, relay states, operating mode, and calibration menu
Programming Built-in 5-key calibrator with English, French, or Spanish language selection
Battery Internal rechargeable NiMH, 12 V DC, 10,000 mAh
Battery Charger 6 A (100 W Max), 100-240 V AC 50/60 Hz input, UL and CE listed
Outputs/Communications 4-20mA, 500 ohms or 0-5 V DC (100mA) by menu selection
2 solid-state Relays, 40 V AC/DC max., rated 250 mA; programmable for flow and/or level alarm or flow proportional pulse (sampler/totalizer, Max frequency 0.4 Hz)
Breakout Box Connections for charger input, external battery input, 2 relays, 4-20mA (0-5 V)
Electrical Surge Protection Sensor, 4-20mA outputs, and AC power input
Data Logger Programmable 2 million point data capacity, time and date stamped plus formatted flow reports including Total, Average, Minimum, Maximum, and times of occurrence. Includes USB output to Flash Drives
Logger Intervals Programmable 10 sec, 30 sec, 1 min, 2 min, 5 min, 10 min, 15 min, 30 min, 60 min
Software Greyline Logger for Windows. Graph and data table presentation, level/velocity to flow conversion, exports data to Excel, exports graphs
Approximate Shipping Weight 6.8 kg (15 lbs)
QZ02L Sensor Specifications
Spec name: Description:
Velocity Measurement Range 0.031 m/s to 6.2 m/s (0.1 ft/s to 20 ft/s) and reverse flow to -1.5 m/s (-5 ft/s)
Level Measurement Range Minimum Head: 25.4 mm (1 in). Maximum Head: 4.57 m (15 ft)
Operating Temperature -15 °C to 80 °C (5 °F to 175 °F)
Exposed Materials 316 stainless steel, epoxy resin, polyurethane
Sensor Cable 7.6 m (25 ft) submersible polyurethane jacket, shielded, 3-coaxial
Sensor Mounting Includes MB-QZ stainless steel mounting bracket
Temperature Compensation Automatic, continuous

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 一级毛片免费在线 | 成人在线小视频 | 小明成人永久免费观看视频 | 美女被免费视频网站九色 | 成人网av | 91国产精品 | 思思99re| 欧美日韩在线免费观看 | 日本黄在线| 日本欧美大码aⅴ在线播放 久久精品一区二区国产 | 草草影院国产 | 免费视频一区二区 | 丁香六月婷婷在线观看视频 | 欧美日韩色黄大片在线视频 | 2023av视频| 亚洲成人看片 | 欧美黄色录像 | 亚洲一区二区约美女探花 | 秋霞操| 日本成人一级 | 国产99在线 | 亚洲 | 成人免费xx | 青青伊人国语 | 婷婷在线视频观看 | 亚洲欧美日韩国产 | 国产免费一区二区三区网站免费 | 欧美在线免费 | 91资源在线 | 欧美日韩国产一区二区三区 | 三级a视频 | 91tm视频| 鲁一鲁综合 | 国产视频一区二区 | 夜夜草视频| 久久三级视频 | 国产亚洲一欧美一区二区三区 | 欧美精品一区二区三区四区五区 | 天堂网亚洲 | 天天爽爽 | 国自产拍在线天天更新91 | 天天怕夜夜怕狠狠怕 |