100Hz is 4 nV/√Hz or less, so for example, even with 1000 x gain, total noise from 100 Hz to 1000 Hz is less than 1 div pe" />

成人亚洲精品777777-成人亚洲精品久久久久-成人亚洲精品久久久久软件-成人亚洲区无码区在线点播-成人亚洲性情网站www在线观看-成人艳情一二三区

Products

current position:home page>Products>Measuring Instrument>ALPHALAB>

Oscilloscope Preamplifier LNA10

Updated:2025-03-13

Views:206

  • Brand: ALPHALAB
  • Model: LNA10
  • Description: With this preamp, sub-microvolt signals can be displayed on scopes which typically only go down to 1mV/div on the vertical axis. The preamp includes an analog true differential input and an analog lo
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Oscilloscope Preamplifier LNA10 Description:

With this preamp, sub-microvolt signals can be displayed on scopes which typically only go down to 1mV/div on the vertical axis. The preamp includes an analog true differential input and an analog low-pass filter (tunable 1Hz-1MHz). Input-referenced RMS noise spectrum for f >100Hz is 4 nV/√Hz or less, so for example, even with 1000 x gain, total noise from 100 Hz to 1000 Hz is less than 1 div peak-to-peak on a 1mV/div vertical scope setting (assuming a low-impedance input). Most oscilloscopes are designed to display high-frequency (fast) events that may intrinsically have noise of a millivolt or more. However, low-frequency signals have much less intrinsic noise, so a low-noise preamp and a bandwidth-limiting filter are essential for small signals at low frequency.* Most amplifiers have a white noise spectrum (a flat spectral curve) at all frequencies above ~1000 Hz. This white noise spectrum is usually specified as a certain number of nV per √Hz. However, unlike typical passive resistors, the equivalent input noise spectrum of solid-state amplifiers (in nV/√Hz) becomes higher at low frequencies. Typically the number of nV/√Hz is proportional to ~1/f for f ≤10Hz. The table below shows actual noise of the LNA 10 in various frequency ranges. At all frequencies, the LNA 10 has much less noise than typical solid-state amplifiers.



Frequency Range:

10-4 – 10-2 Hz (freq range: inverse of 2.8hrs to inverse of 100sec)

10-2 Hz – 1 Hz (freq range: inverse of 100sec to inverse of 1 sec)

1 – 10 Hz

10 – 100 Hz

Above 100 Hz

Input-referenced Noise:

50 nV RMS

20 nV RMS

18 nV RMS (6nV/√Hz average)

39 nV RMS (4.1nV/√Hz)

< 4 NV/√Hz

The intrinsic “white” noise of a resistive electrical circuit at room temperature is proportional to √(R?Δf), which is the square root of the product of source resistance multiplied by the bandwidth being investigated. For low source resistance and low frequencies, noise is low. For example, a 1000 ? resistor will have an intrinsic RMS noise of 13 nV in a Δf =10 Hz bandwidth, with 10 Hz being the bandwidth, for example, associated with the frequency range 0-10 Hz, or with the frequency range 102 Hz-112 Hz. The noise will become twice as much if the bandwidth being studied is 4 times as wide (i.e., 40 Hz), or if the resistance is multiplied by 4.


Features:

Output has a single pole lowpass filter, tunable from 1 Hz to 1 MHz. This feature reduces the bandwidth, as needed.

Selectable DC/AC coupled input (“AC” passes through a .3Hz highpass filter, 1 pole): On DC, each input must be between -0.4V and +0.4V, with respect to case ground, for accurate readings. When set to AC, a DC offset up to +/- 30V can be present. (However, if the inputs rapidly vary by more than .8V peak-to-peak, then the slew rate must be ≤ 2V/sec for accurate amplification.)

Inputs are protected to +/- 5KV static and +/-30V unlimited current transients, with respect to case ground.

Output impedance is 470 Ω.

Selectable gains are 10x, 100x, 1000x (true differential, with CMRR > 90dB). Also positive and negative single-ended inputs can be selected, as well as reference ground. Gain accuracy: +/-1%. (The LNA 10 does not include a 1x gain.)

An offset adjustment, equivalent to +/- 1 mV at the input, is present.

A BNC output (100 ?) is intended to be connected to a single oscilloscope channel, or to another voltage-reading device (data logger, voltmeter, etc).

Additional information:

applications: Electrical Engineering, Scientific Research
category: Voltage Measurement

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 国产在线精品一区二区 | 国产午夜久久精品 | 夜夜夜爽爽爽久久久 | 婷婷啪啪| 91亚色下载| 五月天色区 | 久久综合五月天婷婷伊人 | 黄色片网站在线播放 | 一区二区三区四区毛片 | 奇米7777第四色 | 日韩资源在线观看 | 日韩成人在线观看 | 午夜剧场免费看 | 国产中文在线 | 免费人成综合在线视频 | 精品久久香蕉国产线看观看亚洲 | 亚洲成人av在线 | 日比视频 | 国产伦精品一区二区三区照片91 | 国产精品久久久久久久久久久久久久 | 婷婷亚洲五月色综合 | 国产夜夜爽 | 日本在线播放一区二区三区 | 久久精品欧美日韩精品 | 午夜久久久精品一区二区三区 | 中国女人一级片 | 99热精品在线播放 | 欧美大片日韩精品四虎影视 | 91久久香蕉国产线看 | 亚洲日本成人 | 第二人生完整版免费观看 | 亚洲成人精品在线 | 亚洲人人在线 | 日本亚洲精品无码专区国产 | 午夜在线影院 | 国产视频播放 | 国产伊人久久 | 久草在线视频在线观看 | 大陆一级毛片免费视频观看 | 国产欧美一区二区三区观看 | 欧美狠狠插 |