FTN02 Field thermal needle system

Updated:2025-03-13

Views:185

  • Brand: Hukseflux
  • Model:FTN02
  • Description: FTN02 Field thermal needle system performs accurate on-site (field) measurements of the thermal resistivity and thermal conductivity of soils. Measurements with FTN02 comply with ASTM D5334 and IEEE 4
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

FTN02 Field thermal needle system: User's Manual Datasheet

Thermal Needle Measuring System

FTN02 is a thermal needle measuring system for on-site measurements of thermal conductivity (or the inverse value, resistivity) at depths from the surface down to a depth of 1.5 metre. Due to its robustness and length, FTN02 is the best solution for route-surveying of high-voltage electric power cables and heated pipelines (typical depth of burial of 1.5 m). The measurement method is based on the use of a “thermal needle”. This method employs a heating wire and a temperature sensor in a needle. The FTN02 system consists of the thermal needle, model TP09, mounted on a long lance, LN02, and a control and readout unit CRU02. FTN02 is easy to use. After making a small-diameter access hole, the thermal needle TP09 is brought down to just above the point that must be investigated and then pushed into the local undisturbed soil below. The user performs control and readout of the measurement from the handheld CRU02. The measurement result is generated immediately by the CRU02 from the analysis of the time series of the temperature and the heating power during the heating interval.

Advantages

Suitable for on-site (field) surveys: FTN02 is sufficiently robust to survive rough handling during a typical survey. It performs measurements as a stand-alone unit. The batteries in the CRU02 can be recharged through the cigarette-lighter receptacle in an automobile, using the CA02 car adapter, or from 220/110 VAC using the WSA02 wall socket adapter.

Saving time: With FTN02 there is no need for digging a large-diameter access hole to perform measurements. Because of the lance LN02, drilling a small access hole made with a ground drill, typically 30 mm in diameter, is sufficient. With measurement systems without a lance, such as MTN02, the user has to make a large-diameter access hole or even to dig a trench. A typical measurement requires around 60 s to get to thermal equilibrium plus 300 s for the actual heating interval.

Easy data processing: CRU02 gives an immediate indication of the end result and an indication of the quality of the measurement. It can store 50 measurements. ASTM and IEEE require that the end result is visually checked and recalculated. This is typically done during later analysis of the measured data in a spreadsheet. CRU02 is connected to a PC by using USB.

Local calibration / conformity assessment: The accuracy of the measuring system can be verified (before a survey) by measurement in glycerol. For high accuracy verification against a reference material with formal traceability, CRC05 calibration reference cylinders can be separately purchased.

Suggested Use

  • Route surveys, on-site (field) measurements
  • With extension for laboratory analysis of soil specimens (see TNS02)
  • Areas of Application

  • Geotechnics / soil thermal route analysis
  • Material characterisation / thermal conductivity measurement
  • FTN02 Field thermal needle system Specifications:

    Measurand Thermal conductivity, thermal resistivity
    Measurement range 0.1 to 6 W/(m?K) (all common soils)
    Rated operating temperature range from 0 to +50 °C
    Measurement method absolute measurement per ASTM D 5334-08 and IEEE Standard 442-1981(03)
    Data analysis initial analysis by CRU, final review of measurement on PC (required by ASTM)
    Uncertainty (at 20 °C) +/- (6 % of reading + 0.04) W/(m?K)
    Heating interval 300 s (typical)
    Data storage capacity 50 measurements
    Length LN02 lance 1.4 m
    Length TP09 needle 0.17m
    Diameter TP09 6.3 x 10?3 m
    Data communication USB

    WeChat

    Customer Service QQ

    Customer Hotline:

    010-52867770
    0l0-52867771
    l3811111452
    l7896OO5796

    Technical Supports

    0l0-52867774
    l7896OO5796
    info@dorgean.com
    主站蜘蛛池模板: 久久国产精品一区二区三区 | 成人天堂 | 欧美,日韩,国产精品免费观看 | 日本羞羞的午夜电视剧 | 国内精自线一二三四2021网站 | 精品视频久久久 | www啪啪| 污污的免费视频 | 亚洲jizz日本人 | 亚洲精品色婷婷在线影院麻豆 | 99久久精品全部 | 黄在线免费观看 | 日韩欧美极品 | 欧美午夜理伦三级在线观看 | 成人sese| 美日韩精品 | 免费观看的A在线播放 | 欧美三级一区二区三区 | 亚洲日本一区二区 | 亚洲a网 | 中文字幕免费在线 | 亚洲a色| 成人深夜福利视频 | 2021久久精品国产99国产 | 亚洲精品v日韩精品 | 成人午夜精品一区二区三区 | 高清国产午夜精品久久久久久 | 国产一级一级片 | 色七七亚洲| 精品一区二区三区在线观看 | 国产喷水1区2区3区咪咪爱AV | 国内精品九一在线播放 | 国产综合亚洲欧美日韩一区二区 | 男女性免费视频观看 | 亚洲一二四区性毛片1在线 四虎影音 | 国产精品久久久久无码av | 欧美碰碰97免费视频 | 久热中文字幕在线精品免费 | 91精品一区二区三区久久久久 | 日本精品在线 | 国产精品一区二区久久久久 |