3A-PF-12 7Z02720 Laser Measurement Sensor

Updated:2025-03-13

Views:177

  • Brand: Ophir
  • Model: 3A-PF-12
  • Description: The 3A-PF-12 is a very sensitive thermal power/energy laser measurement sensor for short pulsed lasers. It has a 12mm aperture. It can measure from 15μW to 3W and from 20μJ to 2J. It has a damage thre
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Overview of 3A-PF-12 laser measurement sensor:

The 3A-PF-12 is a very sensitive thermal power/energy laser measurement sensor for short pulsed lasers. It has a 12mm aperture. It can measure from 15μW to 3W and from 20μJ to 2J. It has a damage threshold of up to 1.5J/cm2 for ns pulses and covers the spectral range from 0.15 to 20μm. The sensor comes with a 1.5 meter cable for connecting to a meter or PC interface.

3A-PF-12 Sensor Drawing:

Main parameters:

Absorber Type PF type
Aperture ?12mm
Spectral Range 0.15-20μm
Power Range 15μW-3W
Energy Range 20μJ-2J
Dimensions ?70 W x 30 D (mm)
Max Pulse Energy 2J
Max Average Power Density 3kW/cm2
Response Time 2.5 s
Max Energy Density (for <100ns) 1.5J/cm2
Max Energy Density (for 2ms) 15J/cm2
Max Average Power 3W

Problem summary:

Can the BeamTrack sensor be used to measure the position and size of the pulsed laser?

Because position and size are measured together with power, if the laser pulses at a rate at which the average power can be measured, then position and size can also be measured.

Must a specific sensor be used only with the instrument used when ordering?

Ophir instruments and sensors are calibrated independently. Each instrument has the same sensitivity as the other instrument, and the error is about 2%. Each sensor is calibrated independently of a specific instrument, and its calibration information is contained in the DB15 plug. When the sensor is connected to the instrument, the instrument will read and interpret this information. Since the accuracy of the sensor is usually+/- 3%, the additional 0.2% error that may result from inserting different instruments can be ignored, so it does not matter which calibration instrument is used for a specific calibrated sensor.

What does it mean that the spectral range exceeds the calibrated wavelength range?

The spectral range described at the beginning of the specification represents the range of wavelengths that the sensor can effectively use, even if no precise calibration is specified for that range. This means that the accuracy is specified and guaranteed within the calibrated wavelength range. In a wider range of useful wavelengths, the sensor can be used but its accuracy cannot be guaranteed. Generally speaking, within this wider range, the accuracy will be within ± 15%.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 成人一级黄色毛片 | sis色中色| 国产成人精品综合 | 色网在线观看 | 91精品国产91久久久久久 | 亚洲免费看片 | 草草电影 | 亚洲精品一区二区 | 欧美成人黄色网 | 精品一区二区在线观看 | 国产亚洲精彩视频 | 三级色网 | 国产日韩精品在线观看 | 日本天堂在线 | 亚州精品一区二区三区 | 日韩视频在线免费观看 | 成年影院在线看网站免费 | 久久久亚洲天堂 | 午夜 在线| 久久午夜精品视频 | 日韩精品欧美激情亚洲综合 | 九九九九热精品免费视频 | 天干天干夜天干天天爽 | 91精品国产高清久久久久 | 午夜视频久久久久一区 | 高清av一区 | v片免费在线观看 | 亚洲午夜精品一区二区三区 | 亚洲国产精品久久人人爱 | 久久AV无码乱码A片无码软件 | 久久99国产精品免费观看 | 成人一区在线观看 | 在线视频 亚洲 | 河谷镇第一季 | 国产亚洲精品久久久久久入口 | 亚洲综合第二页 | 精品久久人人做人人爽综合 | 欧美成人高清视频 | 男女无遮挡一进一出性视频 | 天天操天天艹 | 色情一区二区三区免费看 |