www.黄色毛片 I 午夜剧场一级片 I 色婷婷中文 I 五级黄色片 I 日本精品一区二区在线观看 I 国产福利三区 I 午夜黄视频 I av无码av高潮av喷吹免费 I 98超碰在线 I 亚洲夜夜爱 I 嘿咻视频在线观看 I 天天爽夜夜爽视频精品 I 久久久久1 I 欧美一级片网址 I 色老二导航 I 久久久一区二区精品 I 你懂的91 I 亚洲乱码中文论理电影 I 国产黄色免费片 I 亚洲国产精品久久久久秋霞影院 I 99中文字幕 I 中文字幕四区 I 在线三级av I 青青草手机视频 I www.亚洲视频.com I 欧美日韩国产成人高清视频 I 国产精品爱久久久久久久电影 I 免费嗨片首页中文字幕 I 天天色综合4 I 日韩中文字幕免费在线观看 I 久久国产精品网站 I 在线免费观看福利影院 I 成人丁香在线 I 米奇777影视狠狠狠 I 色噜噜狠狠色综合欧洲selulu

Products

current position:home page>Products>optical instrument>Ophir>

3A-P-QUAD 7Z07935 Laser Measurement Sensor

Updated:2025-03-13

Views:140

  • Brand: OPHIR
  • Model: 3A-P-QUAD
  • Description: The BeamTrack series 3A-P-QUAD laser measurement sensor measures laser beam position well as power and energy. It has a 12mm aperture and can measure beam position to 0.15mm accuracy. It measures powe
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Overview of 3A-P-QUAD laser measurement sensor:

The BeamTrack series 3A-P-QUAD laser measurement sensor measures laser beam position well as power and energy. It has a 12mm aperture and can measure beam position to 0.15mm accuracy. It measures power from 160μW to 3W and energy from 30μJ to 2J. It has the P type volume absorber that covers the spectral range from 0.15 to 8μm. The sensor comes with a 1.5m cable that connects it to the electronic box, and another 0.5m cable that connects the box to a Meter or PC interface.

3A-P-QUAD Sensor Drawing:

Main parameters:

Absorber Type P type
Aperture ?12mm
Spectral Range 0.15-8μm
Power Range 160μW-3W
Energy Range 30μJ-2J
Dimensions ?70 W x 30 D (mm)
Max Pulse Energy 2J
Max Average Power Density 0.05kW/cm2
Response Time 2.5 s
Max Energy Density (for <100ns) 1J/cm2
Max Energy Density (for 2ms) 1J/cm2
Max Average Power 3W

Problem summary:

Can the BeamTrack sensor be used to measure the position and size of the pulsed laser?

Because position and size are measured together with power, if the laser pulses at a rate at which the average power can be measured, then position and size can also be measured.

Must a specific sensor be used only with the instrument used when ordering?

Ophir instruments and sensors are calibrated independently. Each instrument has the same sensitivity as the other instrument, and the error is about 2%. Each sensor is calibrated independently of a specific instrument, and its calibration information is contained in the DB15 plug. When the sensor is connected to the instrument, the instrument will read and interpret this information. Since the accuracy of the sensor is usually+/- 3%, the additional 0.2% error that may result from inserting different instruments can be ignored, so it does not matter which calibration instrument is used for a specific calibrated sensor.

What does it mean that the spectral range is beyond the calibrated wavelength range?

The spectral range described at the beginning of the specification represents the range of wavelengths that the sensor can effectively use, even if no precise calibration is specified for that range. This means that the accuracy is specified and guaranteed within the calibrated wavelength range. In a wider range of useful wavelengths, the sensor can be used but its accuracy cannot be guaranteed. Generally speaking, within this wider range, the accuracy will be within ± 15%.