www.黄色毛片 I 午夜剧场一级片 I 色婷婷中文 I 五级黄色片 I 日本精品一区二区在线观看 I 国产福利三区 I 午夜黄视频 I av无码av高潮av喷吹免费 I 98超碰在线 I 亚洲夜夜爱 I 嘿咻视频在线观看 I 天天爽夜夜爽视频精品 I 久久久久1 I 欧美一级片网址 I 色老二导航 I 久久久一区二区精品 I 你懂的91 I 亚洲乱码中文论理电影 I 国产黄色免费片 I 亚洲国产精品久久久久秋霞影院 I 99中文字幕 I 中文字幕四区 I 在线三级av I 青青草手机视频 I www.亚洲视频.com I 欧美日韩国产成人高清视频 I 国产精品爱久久久久久久电影 I 免费嗨片首页中文字幕 I 天天色综合4 I 日韩中文字幕免费在线观看 I 久久国产精品网站 I 在线免费观看福利影院 I 成人丁香在线 I 米奇777影视狠狠狠 I 色噜噜狠狠色综合欧洲selulu

Products

current position:home page>Products>optical instrument>Ophir>

10A-PPS 7Z07904 Laser Measurement Sensor

Updated:2025-03-13

Views:181

  • Brand: OPHIR
  • Model: 10A-PPS
  • Description: The BeamTrack series 10A-PPS laser measurement sensor measures laser beam size and position well as power and energy. It has a 16mm aperture and can measure beam size to 5% accuracy and position to 0.
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Overview of 10A-PPS laser measurement sensor:

The BeamTrack series 10A-PPS laser measurement sensor measures laser beam size and position well as power and energy. It has a 16mm aperture and can measure beam size to 5% accuracy and position to 0.1mm accuracy. It measures power from 20mW to 10W and energy from 6mJ to 2J. The sensor comes with a 1.5m cable that connects it to the electronic box, and another 0.5m cable that connects the box to a Meter or PC interface.

10A-PPS Sensor Drawing:

Main parameters:

Absorber Type Broadband
Aperture ?16mm
Spectral Range 0.19 - 20μm
Power Range 20mW-10W
Energy Range 6mJ-2J
Dimensions ?65 W x 34 D (mm)
Max Pulse Energy 2J
Max Average Power Density 28kW/cm2
Response Time 0.8 s
Max Energy Density (for <100ns) 0.3J/cm2
Max Energy Density (for 2ms) 2J/cm2
Max Average Power 10W

Problem summary:

When using the BeamTrack sensor with StarLab on a PC, can StarLab be used to record position and size data? What is the sampling rate?

StarLab can record the beam position. The power measurement value of Ophir power sensor is recorded 15 times per second. When the BeamTrack sensor is connected to StarLab through Juno, the position/size measurement value is also recorded 15 times per second. When the BeamTrack sensor is connected to the StarLab via the Vegas/Nova II, the position/size measurements are recorded once per second. This is because in Vega/Nova II, the sampling speed for these parameters is slow.

Can the BeamTrack sensor be used to measure the position and size of the pulsed laser?

Because position and size are measured together with power, if the laser pulses at a rate at which the average power can be measured, then position and size can also be measured.

For what type of laser points, the BeamTrack sensor can be used to measure the position and size?

The BeamTrack sensor can measure the position of any beam shape. Only the size of the Gaussian (TEM00) beam can measure the specified accuracy. For other laser modes, the size measurement is relative.

Must a specific sensor be used only with the instrument used when ordering?

Ophir instruments and sensors are calibrated independently. Each instrument has the same sensitivity as the other instrument, and the error is about 2%. Each sensor is calibrated independently of a specific instrument, and its calibration information is contained in the DB15 plug. When the sensor is connected to the instrument, the instrument will read and interpret this information. Since the accuracy of the sensor is usually+/- 3%, the additional 0.2% error that may result from inserting different instruments can be ignored, so it does not matter which calibration instrument is used for a specific calibrated sensor.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com