  • Model: 10A-PPS
  • Description: The BeamTrack series 10A-PPS laser measurement sensor measures laser beam size and position well as power and energy. It has a 16mm aperture and can measure beam size to 5% accuracy and position to 0.
  • Feedback
  • WeChat

    QQ

    Online Service

Product Details

Overview of 10A-PPS laser measurement sensor:

The BeamTrack series 10A-PPS laser measurement sensor measures laser beam size and position well as power and energy. It has a 16mm aperture and can measure beam size to 5% accuracy and position to 0.1mm accuracy. It measures power from 20mW to 10W and energy from 6mJ to 2J. The sensor comes with a 1.5m cable that connects it to the electronic box, and another 0.5m cable that connects the box to a Meter or PC interface.

10A-PPS Sensor Drawing:

Main parameters:

Absorber Type Broadband
Aperture ?16mm
Spectral Range 0.19 - 20μm
Power Range 20mW-10W
Energy Range 6mJ-2J
Dimensions ?65 W x 34 D (mm)
Max Pulse Energy 2J
Max Average Power Density 28kW/cm2
Response Time 0.8 s
Max Energy Density (for <100ns) 0.3J/cm2
Max Energy Density (for 2ms) 2J/cm2
Max Average Power 10W

Problem summary:

When using the BeamTrack sensor with StarLab on a PC, can StarLab be used to record position and size data? What is the sampling rate?

StarLab can record the beam position. The power measurement value of Ophir power sensor is recorded 15 times per second. When the BeamTrack sensor is connected to StarLab through Juno, the position/size measurement value is also recorded 15 times per second. When the BeamTrack sensor is connected to the StarLab via the Vegas/Nova II, the position/size measurements are recorded once per second. This is because in Vega/Nova II, the sampling speed for these parameters is slow.

Can the BeamTrack sensor be used to measure the position and size of the pulsed laser?

Because position and size are measured together with power, if the laser pulses at a rate at which the average power can be measured, then position and size can also be measured.

For what type of laser points, the BeamTrack sensor can be used to measure the position and size?

The BeamTrack sensor can measure the position of any beam shape. Only the size of the Gaussian (TEM00) beam can measure the specified accuracy. For other laser modes, the size measurement is relative.

Must a specific sensor be used only with the instrument used when ordering?

Ophir instruments and sensors are calibrated independently. Each instrument has the same sensitivity as the other instrument, and the error is about 2%. Each sensor is calibrated independently of a specific instrument, and its calibration information is contained in the DB15 plug. When the sensor is connected to the instrument, the instrument will read and interpret this information. Since the accuracy of the sensor is usually+/- 3%, the additional 0.2% error that may result from inserting different instruments can be ignored, so it does not matter which calibration instrument is used for a specific calibrated sensor.

WeChat

Customer Service QQ

Customer Hotline:

010-52867770
0l0-52867771
l3811111452
l7896OO5796

Technical Supports

0l0-52867774
l7896OO5796
info@dorgean.com
主站蜘蛛池模板: 成人福利在线观看 | 国产精品亚洲综合五月天 | 日韩午夜小视频 | 国产精品久久久久婷婷二区次 | 男人女人爽好猛好痛动态图 | 日本网站在线 | 日本黄色免费在线视频 | 男插女高潮一区二区 | 欧美日韩视频在线第一区 | 欧美人妖猛交 | 久久久国产精品入口麻豆 | 91综合网 | 久久久精品综合 | 日韩一区二区三区免费视频 | 精品福利在线观看 | 欧美视频福利 | 免费看叼嘿视频 | 99re热精品视频| 国产精品欧美一区二区三区不卡 | youijzzzfree最新欧美 | 国产日韩在线播放 | 国内毛片视频 | 国产欧美一区二区在线观看 | 成人久久| 日韩aⅴ在线观看 | 日韩一二三区 | 亚洲国产99在线精品一区二区 | 簧片视频在线观看 | 亚洲精彩视频在线观看 | 国产精品视频免费看 | 三级成人AV电影在线观看 | 国产一区日韩二区欧美三区 | 日韩精品在线一区二区 | 成人黄18免费网站 | 99热这里只有精品国产99热门精品 | 精品成人无码A片免费软件 久久这里只有精品免费视频 | 日本久草网 | 很黄很色又很爽的视频 | 狠狠色噜噜狠狠狠狠2021天天 | 久久国 | 国产成人18黄网站在线观看网站 |